Battery
Battery voltage:The voltage (V) of the battery.
240 V
Battery technology:The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Design
Certification:
CE, EAC, IEC 62040-1-1, IEC 62040-2, IEC 62040-3, IEC 62040-4, ISTA 2B, RCM, WEEE
REACH
International Protection (IP) code:The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes".
IP20
Cooling type:The method used to cool the device or to cool the air around the device.
Active
Form factor:The shape or design of the product.
Tower
Features
Noise level:The amplitude level of the undesired background noise, usually measured in decibels (db).
63 dB
Input current Total Harmonic Distortion (THD):
3%
Output voltage Total Harmonic Distortion (THD):
3%
Emergency Power Off (EPO):
Three-phase output voltage supported:
400 V
Number of output phases:
3
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
55 A
Output frequency:
50/60 Hz
Output operation voltage (max):The maximum output voltage produced by the device.
415 V
Output operation voltage (min):The minumum voltage produced by the device during operation.
380 V
Input frequency:The frequency (Hz) which is required to power the product.
45/65 Hz
Input operation voltage (max):The maximum input voltage supported by the device.
477 V
Input operation voltage (min):The minumum voltage needed by the device during operation.
304 V
Output power:The power that the device can produce.
30000 W
Output power capacity:The maximum power that the device can produce.
30 kVA
UPS topology:
Double-conversion (Online)
General
Type:Characteristics of the device.
Uninterruptible Power Supplies (UPSs)
Logistics data
Harmonized System (HS) code:
85078000
Operational conditions
Non-operating altitude:
0 - 15000 m
Operating altitude:
0 - 999.9 m
Storage relative humidity (H-H):
0 - 95%
Operating relative humidity (H-H):
0 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-15 - 40 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C
Technical details
Compliance certificates:
RoHS
Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
152 kg
Height:The measurement of the product from head to foot or from base to top.
1400 mm
Depth:The distance from the front to the back of something.
969 mm
Width:The measurement or extent of something from side to side.
500 mm