Battery
Battery recharge time:Approximate time required to recharge the battery from completely empty to completely full
8 h
Typical backup time at half load:The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
9 min
Typical backup time at full load:The amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
2 min
Number of batteries supported:The number of batteries that can be used with the product.
2
Battery voltage:The voltage (V) of the battery.
12 V
Battery capacity:The amount of electric charge a battery can deliver at the rated voltage. The more electrode material contained in the cell the greater its capacity. A small cell has less capacity than a larger cell with the same chemistry, although they develop the same open-circuit voltage. Capacity is measured in units such as amp-hour (A·h).
7 Ah
Battery technology:The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Design
Certification:
CE, EAC, RCM
Display type:Type of display (screen) e.g. LCD.
LCD
Cable length:How long the cable is.
1.83 m
Features
Audible alarm(s):Alarms that make a sound when they are activated (set off).
Power protection features:Features that protect the device against power problems e.g. overload.
Overload
Surge protection features:
Fax, Modem, Network, Telephone
Number of output phases:
1
Response time:The response time is the time difference between the moment that a source (for example a video card) sends a signal and that equipment (for example a monitor) receives or display the signal. (Used abbreviations: R/F = Rise and Fall.)
4 ms
Surge energy rating:A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
405 J
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
10 A
Automatic Voltage Regulation (AVR):
Input frequency:The frequency (Hz) which is required to power the product.
50/60 Hz
Input operation voltage (max):The maximum input voltage supported by the device.
265 V
Input operation voltage (min):The minumum voltage needed by the device during operation.
165 V
Output power:The power that the device can produce.
780 W
Output power capacity:The maximum power that the device can produce.
1.3 kVA
UPS topology:
Line-Interactive
General
Type:Characteristics of the device.
Uninterruptible Power Supplies (UPSs)
Operational conditions
Non-operating altitude:
0 - 15001 m
Operating altitude:
0 - 3000 m
Storage relative humidity (H-H):
0 - 95%
Operating relative humidity (H-H):
0 - 90%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-15 - 45 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C
Other features
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
230 V
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
230 V
Output connections:
2 x UK & 4 x IEC
Packaging data
Bundled software:Software distributed with another product such as a piece of computer hardware or other electronic device, or a group of software packages which are sold together. A software suite is an example of bundled software, as is software which is pre-installed on a new computer.
PowerPanel Personal Edition
Ports & interfaces
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
2
Serial ports quantity:The number of serial ports in a computer or peripheral. A serial port is a serial communication physical interface through which information transfers in or out one bit at a time. The term "serial port" usually identifies hardware more or less compliant to the RS-232 standard, intended to interface with a modem or with a similar communication device. In modern computers and peripherals, serial ports have largely been replaced by USBs and other interfaces.
1
USB 2.0 ports quantity:Number of USB 2.0 ports (connecting interfaces) in the device. USB 2.0 was released in April 2000 (now called "Hi-Speed"), adding higher maximum signaling rate of 480 Mbit/s (effective throughput up to 35 MB/s or 280 Mbit/s), USB 2.0 ports are usually black.
1
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
6 AC outlet(s)
Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
9.86 kg
Height:The measurement of the product from head to foot or from base to top.
265 mm
Depth:The distance from the front to the back of something.
370 mm
Width:The measurement or extent of something from side to side.
100 mm