Battery
Battery recharge time:Approximate time required to recharge the battery from completely empty to completely full
3 h
Battery life (max):Maximum battery life. Mobile Markâ„¢ (2002) is the standard often used to benchmark battery life time.
5 year(s)
Battery technology:The type of battery in the device, e.g. nickel–cadmium (NiCd).
Sealed Lead Acid (VRLA)
Design
International Protection (IP) code:The IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables below. Where there is no protection rating with regard to one of the criteria, the digit is replaced with the letter X. an electrical socket rated IP22 is protected against insertion of fingers and will not be damaged or become unsafe during a specified test in which it is exposed to vertically or nearly vertically dripping water. Another example is the Sony Xperia Z Ultra, one of the first cellular phones to be IP-rated; it is rated at IP58 and marketed as "dust resistant" and can be "immersed in 1.5 meter of freshwater for up to 30 minutes".
IP20
Display type:Type of display (screen) e.g. LCD.
LCD
Cable length:How long the cable is.
1.83 m
Form factor:The shape or design of the product.
Rackmount
Features
Audible alarm(s):Alarms that make a sound when they are activated (set off).
Noise level:The amplitude level of the undesired background noise, usually measured in decibels (db).
50 dB
Emergency Power Off (EPO):
Surge energy rating:A surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
432 J
Output frequency:
50/60 Hz
Output operation voltage (max):The maximum output voltage produced by the device.
240 V
Output operation voltage (min):The minumum voltage produced by the device during operation.
220 V
Input frequency:The frequency (Hz) which is required to power the product.
40/70 Hz
Input operation voltage (max):The maximum input voltage supported by the device.
150 V
Input operation voltage (min):The minumum voltage needed by the device during operation.
50 V
Output power:The power that the device can produce.
1500 W
Output power capacity:The maximum power that the device can produce.
1.5 kVA
UPS topology:
Double-conversion (Online)
Logistics data
Harmonized System (HS) code:
85078000
Products per pallet:
12 pc(s)
Operational conditions
Storage relative humidity (H-H):
0 - 95%
Operating relative humidity (H-H):
0 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-20 - 50 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 40 °C
Packaging data
Ports & interfaces
Serial interface type:
RJ-45
USB port:Universal Serial Bus (USB) is an industry standard developed in the mid-1990s that defines the cables, connectors and communications protocols used in a bus for connection, communication, and power supply between computers and electronic devices. USB was designed to standardize the connection of computer peripherals (including keyboards, pointing devices, digital cameras, printers, portable media players, disk drives and network adapters) to personal computers, both to communicate and to supply electric power. It has become commonplace on other devices, such as smartphones, PDAs and video game consoles. USB has effectively replaced a variety of earlier interfaces, such as serial and parallel ports, as well as separate power chargers for portable devices.
Technical details
Compliance certificates:
RoHS
Sustainability certificates:
Green Premium
Weight & dimensions
Package weight:Weight of the packaged product.
29.6 kg
Package height:The distance from the top to the bottom of the packaging.
246 mm
Package depth:The distance from the front to the back of the packaging.
749 mm
Package width:The distance from one side of the packaging to the other.
594 mm
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
21 kg
Height:The measurement of the product from head to foot or from base to top.
85 mm
Depth:The distance from the front to the back of something.
505 mm
Width:The measurement or extent of something from side to side.
432 mm