Overview



The APC Switched Rack PDU distributes reliable power within a rack through a single input and multiple output receptacles The APDU9941 offers advanced load management combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management The 0U PDU includes a NEMA L6-30P input plug with 3 05m (10 ft) cord, (21) IEC 60320 C13/C15 and (3) IEC 60320 C19/C21 hybrid outlet receptacles The hybrid outlets allow 60°C operating temperature at full load, are compatible with standard C14 and C20 power cords, and are future-proofed for new C16 and C21 power cords required for higher temperature rated devices The Network Management Card provides enhanced cybersecurity with secured interfaces and modified password policy The rack PDU integrates with EcoStruxure IT through Network Management Card and can be accessed, configured, and managed remotely via Web, SNMP and Command Line Interface Color user-interactive LCD interface details current, real power, voltage, and energy measurements for local user access The outlet level control allows power on/off functionality for power recycling/reboot of remote equipment and restricts unauthorized use of individual outlets The Switched Rack PDU includes a temperature/humidity sensor port, locking IEC outlets when used with locking power cords, low-profile circuit breakers and USB port for local Firmware updates The rack PDU supports daisy-chain of up to 32 PDUs on a single IP address, thereby reducing networking cost The rack PDU comes with a standard three-year warranty




Specification


Technical Description: APC Rack PDU, 9000 switched, 0U, 30A, 200V and 208V, 21 C13 and C15, 3 C19 and C21 sockets

Certificates
Certification:
CUL , FCC 15 A, ICES-003, PSE
Compliance certificates:
RoHS

Certification
Certification:
CUL , FCC 15 A, ICES-003, PSE
Compliance certificates:
RoHS

Design
Product colour:
Black
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
Type:Characteristics of the device.
Single-phase
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Switched

Operational conditions
Non-operating altitude:
0 - 15240 m
Operating altitude:
0 - 3048 m
Operating relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-25 - 65 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
-5 - 60 °C

Packaging content
Manual:
Yes

Packaging data
Package height:The distance from the top to the bottom of the packaging.
2040 mm
Package depth:The distance from the front to the back of the packaging.
124 mm
Package width:The distance from one side of the packaging to the other.
165 mm
Package weight:Weight of the packaged product.
10 kg

Ports & interfaces
Ethernet LAN (RJ-45) ports:Number of Ethernet LAN (RJ-45) ports (connecting interfaces) in the device. Ethernet LAN (RJ-45) ports allow a computer to connect to the ethernet.
1
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
NEMA L6-30P
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
24 AC outlet(s)

Power
Load capacity:
4992 VA
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
200 - 208 V
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
30 A
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
90 - 264 V

Sustainability
Sustainability compliance:
Yes

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
8.5 kg
Height:The measurement of the product from head to foot or from base to top.
1829 mm
Depth:The distance from the front to the back of something.
46 mm
Width:The measurement or extent of something from side to side.
55 mm


Product details


APDU9941 APC

APC Rack PDU, 9000 switched, 0U, 30A, 200V and 208V, 21 C13 and C15, 3 C19 and C21 sockets

£1303.00 and In stock

SKUAPDU9941

APC Rack PDU, 9000 switched, 0U, 30A, 200V and 208V, 21 C13 and C15, 3 C19 and C21 sockets

Quick Code: Q779317 MPN: APDU9941
£1085.83ex VAT

In Stock