Overview



APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager




Specification


Technical Description: APC Rack PDU 2G, Switched, ZeroU, 20A/208V, 16A/230V, (7) C13 & (1) C19

Design
Mounting:
Vertical
Rack capacity:The spase that device fill in rack.
0U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered, Switched

Logistics data
Total carbon footprint (kg of CO2e):
1302.31

Management features
Outlet control:
Lock-out, Recycle, Turn off, Turn on
Monitoring:
Current, Power, Voltage

Ports & interfaces
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
8 AC outlet(s)

Power
Maximum power:The maximum power that can be put into or produced by the device.
3680 W
Maximum total current draw per phase:
16 A
Maximum input current per phase:
16 A
Load capacity:
3680 VA
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
16 A
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
230 V

Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
3.23 kg
Height:The measurement of the product from head to foot or from base to top.
988 mm
Depth:The distance from the front to the back of something.
46 mm
Width:The measurement or extent of something from side to side.
56 mm


Product details


AP8958 APC 0731304277101

APC Rack PDU 2G, Switched, ZeroU, 20A/208V, 16A/230V, (7) C13 & (1) C19

£1133.99 and

SKUAP8958

APC Rack PDU 2G, Switched, ZeroU, 20A/208V, 16A/230V, (7) C13 & (1) C19

Quick Code: Q46468 MPN: AP8958
£944.99ex VAT

Out of Stock